Remote control commands
R&S
®
RTP
2098User Manual 1337.9952.02 ─ 12
Parameters for setting and query:
<SearchName> String with the name of the search.
SEARch:TRIGger:USBPd:DMIN <SearchName>,<Frame>, <Field>, <Data>
SEARch:TRIGger:USBPd:FRAMe<m>:FLD<n>:DMIN <SearchName>,<DataMin>
SEARch:TRIGger:USBPd:FRAMe<m>:FLD<n>:DMIN? <SearchName>
Specifies the data pattern to be searched, or sets the start value of a data pattern
range to be searched.
Suffix:
<m>
.
*
Specifies the frame.
<n> *
Specifies the field number within the frame.
Parameters:
<DataMin> Specifies the name of the generic trigger setting frame, see
SEARch:RESult:USBPd:FRAMe<m>:TYPE? on page 2105.
Parameters for setting and query:
<SearchName> String with the name of the search.
SEARch:TRIGger:USBPd:DOPerator <SearchName>,<Frame>, <Field>, <Operator>
SEARch:TRIGger:USBPd:FRAMe<m>:FLD<n>:DOPerator
<SearchName>,<DataOperator>
SEARch:TRIGger:USBPd:FRAMe<m>:FLD<n>:DOPerator? <SearchName>
Sets the operator to set a specific data pattern to be searched in the selected field of
the selected frame.
Suffix:
<m>
.
*
Specifies the frame.
<n> *
Specifies the field number within the frame.
Parameters:
<DataOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less than or equal, Greater than,
Greater than or equal. These conditions require one endpoint
value to be set using SEARch:TRIGger:USBPd:FRAMe<m>:
FLD<n>:DMIN.
INRange | OORange
In range, out of range. These conditions require a range of end-
point values to be set using SEARch:TRIGger:USBPd:
FRAMe<m>:FLD<n>:DMIN and SEARch:TRIGger:USBPd:
FRAMe<m>:FLD<n>:DMAX.