Protocol analysis
R&S
®
RTP
564User Manual 1337.9952.02 ─ 12
Trigger type
Selects the trigger type for CAN analysis.
"Start of frame"
Triggers on the first edge of the dominant SOF bit (synchronization
bit).
"Frame type"
Triggers on a specified frame type (data, remote, error, or overload).
For data and remote frames, also the identifier format is considered.
For details, see:
"Frame type" on page 566
"ID type" on page 566
"Identifier"
Sets the trigger to a specific message identifier or an identifier range.
See "Identifier setup: Condition, Identifier min, Identifier max"
on page 567.