Protocol analysis
R&S
®
RTP
565User Manual 1337.9952.02 ─ 12
"Identifier +
Data"
Sets the trigger to a combination of identifier and data condition. The
instrument triggers at the end of the last byte of the specified data
pattern.
The identifier conditions are the same as for the "Identifier" trigger
type, see "Identifier setup: Condition, Identifier min, Identifier max"
on page 567. Data conditions are set with "Data setup: DLC, NDB,
Transfer, Condition, Data min, Data max" on page 568.
"Error condi-
tion"
Identifies various errors in the frame, see "Error conditions"
on page 569.