Protocol analysis
R&S
®
RTP
578User Manual 1337.9952.02 ─ 12
The "Frame type" is automatically set to "Data", and the "Identifier" is shown for infor-
mation.
Specific settings for the symbolic trigger are:
Message......................................................................................................................578
Signal trigger...............................................................................................................578
Signal.......................................................................................................................... 578
Condition.....................................................................................................................579
Value, Value min..........................................................................................................579
Value max....................................................................................................................579
Message
Sets the message to be triggered or searched for.
The setting is used by symbolic trigger and symbolic search. Thus, you always trigger
on and search for the same message if symbolic trigger and symbolic search is used at
the same time.
Remote command:
TRIGger<m>:CAN:SYMBolic:MSGValue on page 1652
Signal trigger
Enables the trigger on a specific signal value that is part of the selected message.
Remote command:
TRIGger<m>:CAN:SYMBolic:TSIGnals on page 1652
Signal
Sets the signal name to be triggered or searched for.
CAN and CAN FD (option R&S