Protocol analysis
R&S
®
RTP
641User Manual 1337.9952.02 ─ 12
13.9.5.2 Ethernet search results
To get search results, "Enable" the search. You can minimize, shift or close the search
dialog.
The search results are listed in the search result table and marked in the waveform by
blue lines.
For an introduction to search results, see:
●
Chapter 11.1.2, "Search results", on page 449
●
Chapter 11.4.2, "Display zoom settings", on page 468
Remote commands:
●
SEARch:RESult:ETHernet:WCOunt? on page 1746
●
SEARch:RESult:ETHernet:WORD<m>:TYPE? on page 1748
●
SEARch:RESult:ETHernet:WORD<m>:FTYPe? on page 1748
●
SEARch:RESult:ETHernet:WORD<m>:STATe? on page 1746
●
SEARch:RESult:ETHernet:WORD<m>:STARt? on page 1747
●
SEARch:RESult:ETHernet:WORD<m>:STOP? on page 1747
●
SEARch:RESult:ETHernet:WORD<m>:DESTaddress? on page 1747
●
SEARch:RESult:ETHernet:WORD<m>:SRCaddress? on page 1748
●
SEARch:RESult:ETHernet:WORD<m>:DATA? on page 1749
●
SEARch:RESult:ETHernet:WORD<m>:CRC? on page 1749
●
SEARch:RESult:ETHernet:WORD<m>:DSYMbol? on page 1749
●
SEARch:RESult:ETHernet:WORD<m>:SSYMbol? on page 1750
●
SEARch:RESult:ETHernet:WORD<m>:BYTE<n>:VALue? on page 1750
13.9.5.3 Searching Ethernet data
Prerequisite: A serial bus is configured for the Ethernet signal to be decoded and ana-
lyzed.
The search for events is set up in the following way:
1. Press the [Protocol] key and selet the "Shortcuts" tab.
2. Tap "Setup search".
3. If the dialog box does not contain a search entry, tap the "Add" icon to create one,
as described in "To create a user-defined search" on page 463.
4. Tap "Source" and select the serial bus that is set to Ethernet (e.g. "SerBus1",
unless already selected).
The search dialog for Ethernet protocol analysis is opened.
5. Specify search criteria according to Chapter 13.9.5.1, "Ethernet search setup",
on page 638.
Ethernet 10BASE-T and 100BASE-TX (option R&S