Display Format
Selects the display format for the results of the display table.
Remote command:
BUS<m>:EBTB:DISF on page 1976
13.16.2.4 Configuring 8b/10b
For configuration, you assign the line to the input channel, set the threshold, the
bitrate, and the sync symbol.
For details on configuration settings, see Chapter 13.16.2.1, "8b/10b configuration set-
tings", on page 775.
1. Press the [Protocol] key on the front panel.
2. Select the tab of the bus you want to set up, for example "SB1".
3. In the "Setup" tab, set "Protocol"="8b/10b".
4. Tap the "Signal type" button, and select the used signal type for the measurement.
5. Select the source for the signal type.
6. Tap "Autoset".
7. Check the threshold and bitrate settings. Adjust the values if necessary.
8. Select the "Sync symbol" to be used for decoding.
9. Enable "Decode".