Getting started
R&S
®
RTP
78User Manual 1337.9952.02 ─ 12
Performs a search. Tap the icon and adjust the settings in the sidebar. Tap the diagram
with the waveform to be searched, or drag a rectangle to define a search gate. The
search is performed on the selected waveform.
Cursor
The cursor icon shows the last selected cursor type. A short tap on the icon activates
the selected cursor.
To use another cursor type, select it in the toolbar assist, and adjust the settings.
Tap the diagram where you want to set the cursors, or draw a rectangle in the diagram
to position the cursor lines. The resulting cursor lines measure the selected waveform,
and the results are shown. You can adjust the cursor source, type and position in the
result box. Move the cursor lines by dragging them in the diagram, or by turning the
navigation knob. Pressing the knob switches the parameter to be changed.
Mask Test
Starts the on-screen mask definition and the testing against the defined mask.
Tap the icon and then tap the points that build the mask. To finish the shape definition,
tap "Finish segment" in the toolbar assist. To create a rectangular mask, draw a rectan-
gle on the screen. You can add more segments to the test, and add another test. You
can also move the mask segments on the screen.
To configure the mask test settings, tap the icon in the "Mask" result box.
Histogram
The histogram icon on the toolbar shows the last selected histogram type. A short tap
on the icon activates the selected histogram.
To use another histogram type, select it in the toolbar assist, and adjust the source.
Tap the icon and then drag a rectangle on the diagram to mark the histogram area. The
histogram for the selected waveform appears.
To change settings, touch and hold the histogram area, and the histogram toolbar
assist opens.
Measure
Starts an automatic measurement.
You can run up to 8 automatic measurement groups in parallel. The "Automatic meas-
urment" icon starts the measurement groups one after the other.
A measurement group consists of minimum one measurement, and can consist of
many measurements of the same category. Tap the icon, and select the category and
the measurements in the toolbar assist. Tap the diagram with the waveform to be mea-
sured. To define a measurement gate, draw a rectangle on the screen.
To modify the measurement, double-tap one of the result values.
Quick meas
Performs a set of measurements on the selected waveform or on the selected gate.
You can configure up to 8 measurements to be included in quick measurement.
Tap the icon and then tap the diagram with the waveform to be measured or draw a
rectangle to define the gate.
Operating the instrument