Protocol analysis
R&S
®
RTP
826User Manual 1337.9952.02 ─ 12
"Max"
Sets the end value of an SEU value range if "Condition" (SEARch:
TRIGger:USB:SCONdition) is set to INRange or OORange.
Remote command:
SEARch:TRIGger:USB:WSEU on page 2038
SEARch:TRIGger:USB:SCONdition on page 2032
SEARch:TRIGger:USB:SMIN on page 2032
SEARch:TRIGger:USB:SMAX on page 2032
ET check
Enables the search for an Endpoint Type (ET) that meets specific conditions.
"Condition"
Defining a specific endpoint type or an ET range requires to set the
operator to one of the following: equal, not equal, less than, less than
or equal, greater than, greater than or equal, in range, out of range.
"Min"
Specifies an ET, or sets the start value of an ET range.
"Max"
Sets the end value of an ET range if "Condition" (SEARch:TRIGger:
USB:TCONdition) is set to INRange or OORange.
Remote command:
SEARch:TRIGger:USB:WETCheck on page 2037
SEARch:TRIGger:USB:TCONdition on page 2035
SEARch:TRIGger:USB:TMIN on page 2035
SEARch:TRIGger:USB:TMAX on page 2036
13.18.5.2 USB 2.0 search results
To get search results, "Enable" the search. You can minimize, shift or close the search
dialog.
The search results are listed in the search result table and marked in the waveform by
blue lines.
For an introduction to search results, see:
●
Chapter 11.1.2, "Search results", on page 449
●
Chapter 11.4.2, "Display zoom settings", on page 468
Remote commands:
●
SEARch:RESult:USB:PCOunt? on page 2043
●
SEARch:RESult:USB:PACKet<m>:STATus? on page 2043
●
SEARch:RESult:USB:PACKet<m>:STARt? on page 2042
●
SEARch:RESult:USB:PACKet<m>:STOP? on page 2043
●
SEARch:RESult:USB:PACKet<m>:ADDRess? on page 2039
●
SEARch:RESult:USB:PACKet<m>:DATA? on page 2040
●
SEARch:RESult:USB:PACKet<m>:CRC? on page 2039
●
SEARch:RESult:USB:PACKet<m>:ENDPoint? on page 2040
●
SEARch:RESult:USB:PACKet<m>:ET? on page 2040
●
SEARch:RESult:USB:PACKet<m>:FRAMe? on page 2040
USB (option R&S