Command Reference Interface Commands
Parameter
Description
Parameter
Description
interface-type
interface-number
The interface type and ID.
transceiver
Displays the transceiver information.
alarm
Displays the alarm message of the transceiver. If there is no alarm
message, it is displayed as None.
diagnosis
Displays the diagnostic parameters of the transceiver.
Defaults
N/A
Command
Mode
Privileged EXEC mode
Usage Guide
If you do not specify an interface, the transceiver information of all interfaces is displayed.
Configuration
Examples
The following example displays the transceiver information of interface Gigabitethernet 5/4.
Ruijie#show interfaces GigabitEthernet 5/4 transceiver
Transceiver Type : 1000BASE-SX-SFP
Connector Type : LC
Wavelength(nm) : 850
Transfer Distance :
50/125 um OM2 fiber
-- 550m
62.5/125 um OM1 fiber
-- 270m
Digital Diagnostic Monitoring : YES
Vendor Serial Number : 101680093602489
The following example displays the alarm message of the transceiver of interface Gigabitethernet 5/4.
Ruijie#show interfaces GigabitEthernet 5/4 transceiver alarm
gigabitEthernet 5/4 transceiver current alarm information:
RX loss of signal
The following example displays the diagnostic parameters of the transceiver of interface
Gigabitethernet 5/4.
Ruijie#show interfaces GigabitEthernet 5/4 transceiver diagnosis
Current diagnostic parameters[AP:Average Power]:
Temp(Celsius) Voltage(V) Bias(mA) RX power(dBm) TX
power(dBm)
38(OK) 3.20(OK) 0.04(OK)
-40.00(alarm)[AP] -40.00(alarm)