Configuration Guide AAA Commands
aaa local authentication lockout-time lockout-time
In the range from 1 to 2,147,483,647 in the unit of minutes
The default is 15 minutes.
Global configuration mode
Use this command to configure the length of lockout-time when the login user has attempted for more
than the limited times.
The following example sets the lockout-time period to 5 minutes.
Ruijie#configure terminal
Ruijie(config)#aaa local authentication lockout-time 5
Displays the current configuration of the switch.
Displays the lockout configuration parameter of current login.
Use this command to enable the system to print the syslog informing AAA authentication success.
Use the no form of this command to restore the default setting.
This function is disabled by default.
Global configuration mode
Use this command to enable the system to print the syslog informing aaa authentication success.
The following example disables the system to print the syslog informing aaa authentication success.
Ruijie(config)# no aaa log enable