EasyManua.ls Logo

Santerno Sinus Penta - Page 262

Santerno Sinus Penta
486 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINUS PENTA
PROGRAMMING GUIDE
262/486
C003 Pulse Number
C003 Range 0-5
0: [12] 1: [24]
2: [48] 3: [96]
4: [192] 5: [384]
Default
1
1: [24]
Level
ENGINEERING
Address
1003
Function
This parameter has effect only if C001C002. It represents the min. value of pulses per
period obtained when modulation frequency changes (synchronous modulation).
C004 Silent Modulation
C004
Range
0-1
0: [No]; 1: [Yes]
Default
See Table 81 and Table 85
Level
ENGINEERING
Address
1004
Function
This parameter enables silent modulation. The electric noise due to the switching
frequency is dampened.

Table of Contents

Other manuals for Santerno Sinus Penta

Related product manuals