34.2. List of Parameters C008 to C128
Table 78: List of parameters C008 to C128
Parameter FUNCTION User Level
Parameter FUNCTION User Level
Type of control algorithm BASIC
0: IFD
Type of reference ADVANCED
0: Speed (MASTER mode)
Torque Follower mode BASIC
0: No
Speed feedback from encoder BASIC
0: No
Type of V/f curve BASIC
See Table 84 and Table 88
Phase rotation ENGINEERING
0: No
Rated motor frequency BASIC
50.0 Hz
Rated motor rpm BASIC
1420 rpm
Rated motor power BASIC
See Table 85 and Table 89
Rated motor current BASIC
See Table 85 and Table 89
Rated motor voltage BASIC
Depending on the drive voltage
class
Motor no-load power
ADVANCED
0.0%
Motor no-load current ADVANCED
0%
Motor stator resistance ENGINEERING
See Table 85 and Table 89
Leakage inductance ENGINEERING
See Table 85 and Table 89