SINUS PENTA
PROGRAMMING GUIDE
448/486
57.2. List of Inputs I009 to I013
Table 135: List of programmable inputs I009 to I013
Input FUNCTION User Level
MODBUS
Address
I009
Parameter save
BASIC
1396
I012
EEPROM control
BASIC
1399
I013
Alarm control
BASIC
1400
I009 Parameter save
I009
Range
131 ÷ 2466
131 ÷ 2466
Default
This is not a parameter: at power on and whenever the EEPROM command is
executed, I009 is set to zero.
Level
BASIC
Address
1396
Function
Allows only one parameter to be saved to EEPROM.
The value t
o be saved must be the same as the value set in the Address field of
the parameter concerned.
I012 EEPROM Control
I012 Range 0, 2, 4, 5, 11
0: No Command
2: Restore Backup
4: Save Backup
5: Save Work
11: Restore Default
Default
This is not a parameter: at power on and whenever the EEPROM command is
executed, I012 is set to zero.
Level
BASIC
Address
1399
Function
This parameter saves and restores the entire set of parameters that can be
accessed by the user:
2: Restore Backup: the parameters stor
ed in the Backup zone are copied and
stored in the WORK zone. They represent the new RAM parameterization; the
previous RAM parameters are cleared. Backup
RAM
Work;
4: Save Backup
: the parameters in the WORK zone are saved to a copy of the
Backup zone. Work
Backup;
5: Save Work
: the current values of the parameters stored in the RAM zone are
saved to non-
volatile memory in the Work zone. All the parameters are saved
with this command. RAM
Work;
11: Restore Default: factory-setting values are rest
ored for all parameters; each
factory-setting value is stored to non-volatile memory in the Work zone.
Default
RAM Work.

Table of Contents

Other manuals for Santerno Sinus Penta

Related product manuals