PROGRAMMING GUIDE
SINUS PENTA
189/486
Variable A Selected for MDO1 (2,3,4): P271, (P280, P289, P298)
This selects the digital signal or the analog variable used for Test A (set with P273/P282/P291/P300).
The whole list of the selectable items and their description appears at the end of this section (see Table 48).
If a digital signal is selected, Test A is not performed: therefore, the comparison value for Test A (set with
P275/P284/P293/P302) has no meaning.
NOTE
This parameter can be accessed only if the operating mode of the digital output concerned
is other than zero. Example: MDO1 P270≠0.
Variable B selected for MDO1 (2,3,4): P272, (P281, P290, P299)
This selects a different digital signal or the analog variable used for Test B (set with P274/P283/P292/P301).
The whole list of the selectable items and their description appears at the end of this section (see Table 48).
If a digital signal is selected, Test B is not performed: therefore, the comparison value for Test B (set with
P276/P285/P294/P303) has no meaning.
NOTE
Parameter P272 cannot be accessed when the digital output operating mode is 1:
DIGITAL or 3: ANALOG.
Example: MDO1 P270=1 OR P270=3.
Table 48: List of the selectable digital inputs and analog outputs
Selectable digital signals (BOOLEAN):
Drive running (no standby)
Inverter ok: no alarms tripped
Drive KO: alarm tripped when the drive is running
Speed (measured or estimated) higher than +0.5 rpm
Speed (measured or estimated) lower than –0.5 rpm
Drive in limiting mode operating as a motor
Drive in limiting mode operating as a generator
Drive in limiting mode (generator or motor)
Capacitor Precharge relay closure and command return test
PID output max. saturation
PID output min. saturation
Selected MDI1digital input (remote OR physical)
Selected MDI2 digital input (remote OR physical)
Selected MDI3 digital input (remote OR physical)
Selected MDI4 digital input (remote OR physical)
Selected MDI5 digital input (remote OR physical)
Selected MDI6 digital input (remote OR physical)
Selected MDI7 digital input (remote OR physical)
Selected MDI8 digital input (remote OR physical)
ENABLE function (remote AND physical)
ENABLE-SW function (remote AND physical)
MDI1 Digital input (remote OR physical) DELAYED by MDI timers
MDI1 Digital input (remote OR physical) DELAYED by MDI timers
MDI1 Digital input (remote OR physical) DELAYED by MDI timers
MDI1 Digital input (remote OR physical) DELAYED by MDI timers
MDI5 Digital input (remote OR physical) DELAYED by MDI timers
MDI6 Digital input (remote OR physical) DELAYED by MDI timers
MDI7 Digital input (remote OR physical) DELAYED by MDI timers
MDI8 Digital input (remote OR physical) DELAYED by MDI timers
ENABLE function (remote AND physical) DELAYED by MDI timers
Speed tracking error: |SetPoint – Measure| > Error_Par