SINUS PENTA
PROGRAMMING GUIDE
236/486
30.3. List of Parameters P350 to P385
Table 65: List of parameters P350 to P385
Parameter FUNCTION User Level
DEFAULT
VALUES
MODBUS
Address
P350
MPL1: Digital output mode
ADVANCED
0: DISABLE
950
P351
MPL1: Selecting variable A
ADVANCED
D0: DISABLE
951
P352
MPL1: Selecting variable B
ADVANCED
D0: DISABLE
952
P353
MPL1: Testing variable A
ADVANCED
0: >
953
P354
MPL1: Testing variable B
ADVANCED
0: >
954
P355
MPL1: Comparing value for Test A
ADVANCED
0
955
P356
MPL1: Comparing value for Test B
ADVANCED
0
956
P357
MPL1: Function applied to the result of the 2 tests
ADVANCED
0: (A) OR (B)
957
P357a
MPL1: Selecting variable C
ADVANCED
D0: DISABLE
932
P357b
MPL1: Function applied to the result of f(A,B) C
ADVANCED
0: f(A,B) OR C
933
P358
MPL1: Output logic level
ADVANCED
1: TRUE
958
P359
MPL2: Digital output mode
ADVANCED
0: DISABLE
959
P360
MPL2: Selecting variable A
ADVANCED
D0: DISABLE
960
P361
MPL2: Selecting variable B
ADVANCED
D0: DISABLE
961
P362
MPL2: Testing variable A
ADVANCED
0: >
962
P363
MPL2: Testing variable B
ADVANCED
0: >
963
P364
MPL2: Comparing value for Test A
ADVANCED
0
964
P365
MPL2: Comparing value for Test B
ADVANCED
0
965
P366
MPL2: Function applied to the result of the 2 tests
ADVANCED
0: (A) OR (B)
966
P366a
MPL2: Selecting variable C
ADVANCED
D0: DISABLE
934
P366b
MPL2: Function applied to the result of f(A,B) C
ADVANCED
0: f(A,B) OR C
935
P367
MPL2: Output logic level
ADVANCED
1: TRUE
967
P368
MPL3: Digital output mode
ADVANCED
0: DISABLE
968
P369
MPL3: Selecting variable A
ADVANCED
D0: DISABLE
969
P370
MPL3: Selecting variable B
ADVANCED
D0: DISABLE
970
P371
MPL3: Testing variable A
ADVANCED
0: >
971
P372
MPL3: Testing variable B
ADVANCED
0: >
972
P373
MPL3: Comparing value for Test A
ADVANCED
0
973
P374
MPL3: Comparing value for Test B
ADVANCED
0
974
P375
MPL3: Function applied to the result of the 2 tests
ADVANCED
0: (A) OR (B)
975
P375a
MPL3: Selecting variable C
ADVANCED
D0: DISABLE
936
P375b
MPL3: Function applied to the result of f(A,B) C
ADVANCED
0: f(A,B) OR C
937
P376
MPL3: Output logic level
ADVANCED
1: TRUE
976
P377
MPL4: Digital output mode
ADVANCED
0: DISABLE
977
P378
MPL4: Selecting variable A
ADVANCED
D0: DISABLE
978
P379
MPL4: Selecting variable B
ADVANCED
D0: DISABLE
979
P380
MPL4: Testing variable A
ADVANCED
0: >
980
P381
MPL4: Testing variable B
ADVANCED
0: >
981
P382
MPL4: Comparing value for Test A
ADVANCED
0
982
P383
MPL4: Comparing value for Test B
ADVANCED
0
983
P384
MPL4: Function applied to the result of the 2 tests
ADVANCED
0: (A) OR (B)
984
P384a
MPL4: Selecting variable C
ADVANCED
D0: DISABLE
938
P384b
MPL4: Function applied to the result of f(A,B) C
ADVANCED
0: f(A,B) OR C
939
P385
MPL4: Output logic level
ADVANCED
1: TRUE
985