Example 2: Speed references alternatively selected
The two REF analog inputs are to be used as alternative speed references. The following parameters shall be
programmed accordingly:
Type of Reference for REF Input
Value of REF Input producing Min. Reference
Percentage of Ref_Min producing Min. Reference
Value of REF Input producing Max. Reference
Percentage of Ref_Max producing Max. Reference
Type of Signal over AIN1 input
Value of AIN1 Input producing Min. Reference
Percentage of Ref_Min producing Min. Reference
Value of AIN1 input producing Max. Reference
Percentage of Ref_Max producing Max. Reference
As MDI6 input is selected as reference source selection (C179), the references selected via C143 and C144 are
selected as the main reference depending on the input status. When the input is inactive, REF will be the main
reference; when the input is active, AIN1 will be the actual reference.