SINUS PENTA
PROGRAMMING GUIDE
432/486
I080 IP Address Reset
I080 Range
0 ÷ 1
0 Inactive
1 Address reset
Default
This is not a parameter: the input is set to zero at power on and whenever the
command is executed.
Level
ENGINEERING
Validity
Boards: B40
Modbus TCP-IP and Profinet
Address
519
Function
Pressing the button forces the following after the board is reset:
IP 192.168.0.2
subnet mask 255.255.255.0
gateway 0.0.0.0
and DHCP disabled.
This parameter is active only for Modbus TCP-IP and Profinet fieldbus with B40
boards.