PROGRAMMING GUIDE
SINUS PENTA
87/486
P264a Circular Navigation
P264a Range
0 ÷ 1
Function
Parameter P264a is factory set to 1:[YES]. This means that “wrap” navigation is
activated: navigation starts from the first page of the selected menu. Press ▲
to the next page. When the last page is displayed, press ▲ again to
first page of the selected menu.
From the first page of the selected menu, press ▼
to go to the last page of the
active menu.
If P264a=0: [NO], when the last page of the active menu is displayed, the ▲
disabled; you can only view the previous pages—
up to the first page of the active
menu—by pressing the ▼ key.
P264b Navigation Mode with the MENU Key
P264b Range
0 ÷ 1
0: [STANDARD]
1: [OPERATOR]
Function
Press the MENU key from any parameter to go to the access page of the menu
containing that parameter; press the MENU key again to go to the Root page; press
the MENU key again to go to the Keypad page.
If factory setting is active (P264b=0: [STANDARD]) press the MENU
Keypad page to go to the Root page, then to the starting parameter. If P264b
=1:
[OPERATOR], navigation is locked once the Keypad Page is displayed. Hold down
the ESC key for a few seconds to resume navigation.
This prevents inexpert users
from navigating through the parameters stored to the keypad. If the Keypad page is
preset as the startup page (P265=1: [Measures]) and P264b
=1 :[OPERATOR],
navigation is always locked.
P265 Startup Page
P265 Range
0 ÷ 3
1: [Measures]
2: [Keypad]
Function
P265 sets the page to be displayed when the drive is turned on.
P265 = 0: the Root page is the startup page.
P265 = 1: the Keypad Page displaying 4 measures only is the startup page.
P265 = 2: The Keypad page displaying a reference in line 4 is the startup page.
P265 = 3: the START-UP MENU is the startup page.