RM0033 Rev 9 215/1381
RM0033 Analog-to-digital converter (ADC)
255
The total number of conversions in the injected group must be written in the L[1:0] bits
in the ADC_JSQR register.
If the ADC_SQRx or ADC_JSQR registers are modified during a conversion, the current
conversion is reset and a new start pulse is sent to the ADC to convert the newly chosen
group.
Temperature sensor, V
REFINT
and V
BAT
internal channels
The temperature sensor is connected to channel ADC1_IN16 and the internal reference
voltage V
REFINT
is connected to ADC1_IN17. These two internal channels can be selected
and converted as injected or regular channels.
The V
BAT
channel (connected to channel ADC1_IN18) can also be converted as an injected
or regular channel.
Note: The temperature sensor, V
REFINT
and the V
BAT
channel are available only on the master
ADC1 peripheral.
10.3.4 Single conversion mode
In Single conversion mode the ADC does one conversion. This mode is started with the
CONT bit at 0 by either:
setting the SWSTART bit in the ADC_CR2 register (for a regular channel only)
setting the JSWSTART bit (for an injected channel)
external trigger (for a regular or injected channel)
Once the conversion of the selected channel is complete:
If a regular channel was converted:
The converted data are stored into the 16-bit ADC_DR register
The EOC (end of conversion) flag is set
An interrupt is generated if the EOCIE bit is set
If an injected channel was converted:
The converted data are stored into the 16-bit ADC_JDR1 register
The JEOC (end of conversion injected) flag is set
An interrupt is generated if the JEOCIE bit is set
Then the ADC stops.
10.3.5 Continuous conversion mode
In continuous conversion mode, the ADC starts a new conversion as soon as it finishes one.
This mode is started with the CONT bit at 1 either by external trigger or by setting the
SWSTART bit in the ADC_CR2 register (for regular channels only).
After each conversion:
If a regular group of channels was converted:
The last converted data are stored into the 16-bit ADC_DR register
The EOC (end of conversion) flag is set
An interrupt is generated if the EOCIE bit is set

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ST STM32F207 series and is the answer not in the manual?

ST STM32F207 series Specifications

General IconGeneral
BrandST
ModelSTM32F207 series
CategoryMicrocontrollers
LanguageEnglish

Related product manuals