CARE AND MAINTENANCE 7
MHL360 E 7.71
7.7.18 Heater and air conditioning air filter
In order to prevent the heater from becoming
contaminated, the circulating air/fresh air is
drawn in through the air filter (behind the driv-
er’s seat).
In dusty ambient conditions, the air cleaner
fleece should be cleaned or changed every
100 operating hours.
►
Release the quick closures (326/2) on the
cover plate (326/1) and fold away the cover
plate.
►
Remove the frame (327/1), clean or if nec-
essary replace the fleece (327/2).
► When inserting the fleece, ensure that the
blue side of the fleece is facing the rear
wall of the cab.
7.7.19 Supplementary heating
The combustion air is drawn in through the air
filter (rear of cab). In the event of high exposure
to dust, the air filter element should be changed
every 100 operating hours.
h Chapter 7.6.4 Maintenance and inspection
plan
The following maintenance work must be car-
ried out before each heating period:
►
Check glow plug (329/1) for burn-off and
replace if necessary.
►
Examine the fuel filter for clogging and
replace if necessary.
►
Check that electrical connections are se-
curely fastened.
►
Check that fuel lines and connections are
not leaking.
Check the air filter element for dirt.
Fig. 326 Cover plate
Fig. 327 Fleece
Fig. 328 Air filter for supplementary heating
Fig. 329 Supplementary heating