Unit returns the Number of stored Events, which remain Unread, (over remote control) in the form xxx (0-255).
Example: NUE=126
Unit returns the oldest 5 Stored Events which have not yet been read over the remote control in the reply
format
[CR]sub-body[CR]sub-body[CR]sub-body[CR]sub-body[CR]sub-body, where:
sub-body=ABCddmmyyhhmmss, where:
A is the fault/clear indicator:
F=Fault
C=Clear
I=Info
B is the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Info (Power on/off, or log cleared)
5=Open Network
6=BUC
7=LNB
C is Fault Code number, as in FLT? or Info Code, which may be:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
5=Fractional CnC License is expiring.
6=Time Limited CnC License is expiring.
7=Fractional CnC is in use.
ddmmyy = date stamp.
hhmmss = time stamp.
If there are less than 5 events to be retrieved, the remaining positions are padded with zeros. If there are no