Used to set the sample interval for the Statistics Logging Function in the form x, where:
x= 0 to 9 in 10 minute steps.
Note: Setting this parameter to 0 disables the statistics logging function.
Unit returns the number of stored Statistics, which remain Unread (over remote control) in the form xxx,
where:
x = 0-255
Unit returns the oldest 5 Stored Statistics, which have not yet been read over the remote control in the reply
format [CR]sub-body[CR]sub-body[CR]sub-body[CR]sub-body[CR]sub-body, where sub-body=
AA.ABB.BC.CD.Dddmmyyhhmmss:
AA.A=Minimum Eb/No during sample period.
BB.B=Average Eb/No during sample period.
C.C=Max. Tx Power Level Increase during sample period.
D.D=Average Tx Power Level Increase during sample period.
ddmmyy = date stamp.
hhmmss = time stamp.
If there are no new events, the unit replies with RNS*. If there are less than 5 statistics to be retrieved, the
remaining positions are padded with zeros.