Handheld Data Format Requirements General
Product Reference Guide 499
Code 39-Pharmacode (Code 32)
Check character must be included in label data
Label length including start, stop and check characters and excluding pre-
fix character must meet requirements imposed by the main scanner’s
fixed or variable label length control for this symbology type.
Start and stop characters “*” must be included in label
Prefix must be an ASCII character ‘p’
Example: ‘p*123456789*’
Interleaved 2 of 5 (I 2 of 5)
Check character must be included in label data
Label length including check characters and excluding prefix character
must meet requirements imposed by the main scanner’s fixed or variable
label length control for this symbology type.
Prefix must be an ASCII character ‘i’
Example: ‘*i0123456789’
Codabar
Check character must be included in label data
Label length including check character and excluding prefix character
must meet requirements imposed by the main scanner’s fixed or variable
label length control for this symbology type.
Prefix must be an ASCII character ‘%’
Start stop character sets must meet the matching requirement set forth by
the scanner configuration item CI_CBAR_START_STOP_CHAR_MATCH
Start stop character sets s must be of the form ABCD/ABCD and must be
included in the label
Example: ‘%s$99.95s’
Code 128
Prefix must be an ASCII character ‘#’
Label length excluding prefix character must meet requirements imposed
by the main scanner’s fixed or variable label length control for this sym
-
bology type.
Function characters may be transmitted as a hexadecimal value 8x. Where
x correlates to function characters 1 thru 4 as follows:
•x80 = function code 1
•x81 = function code 2
•x82 = function code 3
•x83 = function code 4
For Code128 programming labels the format is of the general form ‘#/
82nnnnn/r ‘ - /82 is hexadecimal 82 and /r is carriage return
Example: ‘#Code_128.Test’
MSI Plessey
Check character must be included in label data

Table of Contents

Other manuals for Datalogic Magellan 9300i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 9300i and is the answer not in the manual?

Datalogic Magellan 9300i Specifications

General IconGeneral
Input voltage100 - 240 V
Input frequency50 - 60 Hz
Power source typeAC
Power consumption (standby)11 W
TypeBuilt-in bar code reader
Sensor type-
Scanner type1D/2D
Light levels (direct sunlight)0 - 86080 lx
Linear (1D) barcodes supportedGS1 DataBar Expanded, GS1 DataBar Omnidirectional, JAN, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, Micro QR Code, QR Code
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Standard interfacesRS-232
Connectivity technologyWired
Product colorBlack, Grey
Built-in displayNo
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Weight- g

Related product manuals