EasyManua.ls Logo

Dodge Sprinter 2006 - Page 2047

Dodge Sprinter 2006
2315 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A/C PRESSURE TRAN SDU CER VOLTAGE
Voltage Possible Cause
0.0 1. No transducer supply voltage from ATC control module.
2. Shorted transducer circuit.
3. Faulty transducer.
0.150 to 0.450 1. Ambient temperature below 10° C (50° F).
2. Low refrigerant system pressure.
0.451 to 4.519 1. Normal refrigerant system pressure.
4.520 to 4.850 1. High refrigerant system pressure.
5.0 1. Open transducer circuit.
2. Faulty transducer.
REMOVAL
WARNING: Refer to the applicable warnings and
cautions for this system before performing the fol-
lowing operation (Refer to 24 - HEATING & AIR
CONDITIONING/PLUMBING - WARNINGS) and (Refer
to 24 - HEATING & AIR CONDITIONING/PLUMBING -
CAUTIONS). Failure to follow the warnings and cau-
tions could result in possible personal injury or
death.
(1) Recover th e refriger ant from th e refriger ant
system (Refer t o 24 - HEATING & AIR CONDITION-
ING/PLUMBING - STANDARD P ROCEDURE).
(2) Disconn ect and isolate the battery nega tive
cable.
(3) Disconn ect the wire ha rness connector from th e
A/C pressure tra nsducer (Fig. 10).
(4) Usin g an open en d wrench , rem ove the A/C
pr essu re tra nsdu cer fr om th e fitting on the liquid
line .
(5) Remove the O-rin g seal from the A/C pr essure
transdu cer and disca rd.
INSTALLATION
(1) Lubricate a n ew O-ring sea l wit h clea n refr ig-
eran t oil a nd install it on t he A/C pressu re tr ans-
du cer.
(2) Usin g an open end wren ch, install a nd tight en
the A/C pr essu re tran sdu cer into th e fitting on the
liquid line. Tighten t he tra nsducer to 12 N·m (106 in.
lbs.).
(3) Reconnect the wir e ha rness connector to th e
transdu cer.
(4) Reconnect t he battery negative cable.
(5) Eva cuate the refrigera nt system (Refer to 24 -
HEATING & AIR CONDITIONING/PLUMBING -
STANDARD PROCE DURE ).
Fig. 10 A/C Pressure Transducer
1 - WIRE HARNESS CONNECTOR
2 - A/C PRESSURE TRANSDUCER
3 - O-RING SEAL
4 - LIQUID LINE FITTING
VA CONTROLS-FRONT 24 - 15