EasyManua.ls Logo

Dynex DSX - 4.3 System Problems

Dynex DSX
358 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Problems
4-6 DSX™ System Service Manual
4.3 System Problems
Note: The application program displays a number of messages on the
display during the normal operation of the system. If a fault occurs, it is
likely that an error message will be presented. These messages are
designed to help you locate the cause of the problem, and they often
suggest possible solutions.
4.3.1 Communication Problems
This section describes situations in which information from the computer cannot be
transmitted to the system or vice versa.
Table 4-3 Troubleshooting Communication Problems
Symptom Probable Cause Resolution
Application Error
REVEL caused a
General
Protection Fault.
A fault has occurred in
the program.
Close down the program and Windows and
try again. If the problem persists, reload the
program.
Checksum Error
in File.
A file has become
corrupted.
If the file is a test, plate data, or curve data
file, recreate it.
Command Failed.
A memory conflict has
occurred between
applications.
Close down the program Windows and try
again.
Command retry
error.
Command Time
out.
An error has occurred
while sending the
commands to a
module.
Check the communication settings and
cables.
Computer control
command error.
The command was
not accepted by the
module.
Check the communication settings and
cables.
Device
already/not open.
The command was
not accepted by the
module
Check the communication settings and
cables.
Directory nnn
does not exist.
Program could not
find the specified
directory
Make sure the drive and directory are correct.