iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual Issue 2.5
117
Table 4.4.4.4-1 ISDN ATTRIBUTES
The ISDN Screening Indicator can configure.
User-Provided, No Service
User-Provided, Pass
User-Provided, Fail
Network Provided.
User-
Provided, No
Service
When the incoming CLI starts with “+,” this value will be
inserted in the place of the “+” sign.
Send progress indication with in-band information in Call
proceeding and Alerting messages.
Send progress indication with in-band information in the
Disconnect message.
Disconnect with
Inband Info
When the system receives a DISCONNECT message with
Inband information from PSTN, the following option can be
applied:
Ignore Inband information: Line is disconnected
Bypass Inband information: Progress Information is
transferred
Wait Release: The system wait to send a Release
message till the other party is disconnected
ISDN clock synchronization is working when “Network Time &
Date”(PGM195) is set to “ISDN CLOCK” and “ISDN Clock
Sync” (PGM143) is ON. It could be controlled by CO line base.