4.4.19.1 Redundancy Attributes PGM 502
Selecting Redundancy attributes will display the page shown. Click the [Save] button after changing Value.
Figure 4.4.19.1-1 Redundancy Attributes
The Redundancy attributes enable redundancy and activate “Geographical” redundancy.
Table 4.4.19.1-1 Redundancy Attributes
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
CPU Redundancy
usage
When redundancy is employed, this field informs the master
UCP that a redundant UCP is available.
OFF
ON
OFF
Change Active UCP
By Power Fail
When power fails, the active UCP is changed to the standby
mode, and the standby UCP becomes active.
OFF
ON
OFF
Geographical
Redundancy
Geographical redundancy permits the remote location of the
redundant UCP modules.
OFF
ON
OFF