4.4.4.13 DCOB CO Line Attributes - PGM 153
Selecting DCOB CO Line Attributes will display the DCOB Line Attributes data input page. Enter a valid CO
range and click the [Load] button to enter the DCOB Line Attributes data. Use the checkmark to indicate
which attributes to modify; checked attributes are stored by clicking the [Save] button.
Enter CO Range: eMG80/100: 1-74 / eMG800: 1-600 / UCP: 1-998
Figure 4.4.4.13-1 DCOB CO Line Attributes
Table 4.4.4.13-1 DCOB LINE ATTRIBUTES
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
Line Status
This parameter defines the code that the system will send to
indicate idle line status following E1R2 specifications.
1~9
6
DNIS Service
In R2, this field determines whether the system will send
caller information to PX or not.
OFF
ON
OFF
Number of CLI
Digits
This parameter defines the number of digits expected as the
Calling Line Identification from digital CO lines.
01~15
10
DCOB Type
According to this type, the line can be restricted to the type of
service, incoming DID, and outgoing calls (DOD).
DID/DOD,
DOD,
DID
DID
Call Category
This parameter defines the code sent in response to a call
category request from the network following E1R2
specifications.
1~9
1
Number of Digits
Expected from DID
circuit
This parameter defines the number of digits expected as DID
digits from digital CO lines. If set to “0”, the number of digits
defined in PGM 145 is used.
0~32
0