131
Table 4.4.4.12-1 T1 CO LINE ATTRIBUTES
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
OP RATE
For Pulse signaling, defines the duration and make/break ratio
of each pulse.
60-40(10pps), 66-33(10pps), 60-40(20pps), 66-33(20pps)
Refer to
description
60-40
(10pps)
SEZ DTC
This timer defines the length of a valid ‘line seizure’ signal.
0~127
(20 ms)
3
RELEASE
For Ground Start, this timer defines the minimum time ground
will not be applied to the TIP side from the PSTN.
0~127
(20 ms)
7
IASG TY
Incoming Address Signaling Type defines the type of signaling
(DTMF or Pulse) expected.
PULSE/
DTMF
DTMF
RING DTC
The Ring DTC (detect) timer defines the minimum acceptable
length of the Ring-on time during a ring cycle.
2~9
(100 ms)
2
RING STOP
The Ring Stop timer defines the maximum Ring-off time during
a ring cycle.
10~60
(100 ms)
60
COLLECT DGT
Collect DGT (digits) defines the number of digits expected on a
DID line.
1~6
3
STORE TIME
For DID lines, this timer defines the maximum delay between
incoming DID digits.
1~15
(second)
15

Table of Contents