iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual Issue 2.5
248
4.3.9.11 Registration & Fractional Module Table – PGM 235
When multiple iPECS eMG are located on the same LAN, it may be desirable to register add-on devices
employing the Registration Table.
REGISTRATION TBL
ENTER TBL NO(1-5)
Press the [PGM] button and dial 235, and enter Table number (Ex.1).
REG TBL 1: NO MAC INFO
MAX PORT : 00, DEV ID: . . . .
Use the dial-pad to select a Table entry (1~5).
Press the desired Flex button; refer to Table 3.3.9.11-1.
Use the dial-pad to enter the desired data. Refer to Table 3.3.9.11-1.
Press the [Save] button to store the data entry.
Table 3.3.9.11-1 MAC REGISTRATION (PGM 235)
TBL 1: SET MAC ADDR
MAC 1: . . . . . . . . . . . . . . . .
Enter the MAC address of the
device to register.
TBL 1: SET MAX PORT
NO OF PORT: 00
Enter the maximum number of
ports (channels) for the device.
For a 00 entry, the system will
accept a physical port number.
TBL 1: DEVICE ID
DEVICE ID : ....
Enter device ID when it has
multiple device ID in
Board/Gateway.