iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual Issue 2.5
88
4.4.2.16 Station ICM Group - PGM 125
Selecting Station ICM Tenancy Group displays the Station ICM Tenancy Group input page. Select ICM
Tenancy Group and click [Load]. The system will display the ICM Tenancy Group Characteristics. Enter the
Station number of the group Attendant and check the appropriate box to allow calling to the group. Click the
[Save] button after changing Value to apply.
Figure 4.4.2.16-1 Station ICM Group
Stations can be assigned to an ICM group under the ‘Common Attributes section. It can be defined up to 15
Tenant groups for eMG80/100(up to 32 for eMG800 and up to 100 for UCP). Each group is configured to allow
or deny placing intercom calls, including transfers, to stations in other groups, and an Attendant station can be
defined for each group. The Attendant will receive “dial 0” calls and controls Day/Night mode for the group.
Table 4.4.2.16-1 STATION ICM GROUP ATTRIBUTES
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
Tenancy ATD
Attendant station for the ICM Tenant group
ATD receives dial ‘0’ calls and controls Day/Night Service.
Station No.
Group Access
ICM tenancy groups allowed access by stations of the
selected group.
eMG80/100:1~15
eMG800:1~32
UCP:1~100
1