EasyManua.ls Logo

iPECS UCP600 - Page 303

iPECS UCP600
721 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual Issue 2.5
289
Table 4.4.9.1-1 LCR Control Attribute
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
LCR Access
Mode
This entry defines the effective LCR modes, the modes by which
the user can access LCR.
Disable
Only Loop LCR
Internal and Loop LCR
Loop and Direct CO LCR
Internal, Loop, and Direct CO LCR
Internal, Loop, Direct CO, and Direct Loop LCR
Refer to
description
Disable
Day Zone
Each day of the week is assigned to a Day Zone (1~3). The active
Day Zone is the Zone assigned to the current day of the week.
Zone1~3
(days of the
week)
Zone 1
Time Zone1
This entry defines the hours of the day during which each Zone is
active for Time Zone 1. Note hours not defined in Time Zone 2 and
3 are automatically part of Time Zone 1.
00~24
00~24
Time Zone2
This entry defines the hours of the day during which each Zone 2 is
active for Time Zone 2. Note hours not defined in Time Zone 2 and
3 are automatically part of Time Zone 1.
00~24
00~24
Time Zone3
This entry defines the hours of the day during which Zone 3 is
active for Time Zone 3. Note hours not defined in Time Zone 2 and
3 are automatically part of Time Zone 1.
00~24
00~24

Table of Contents