iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual Issue 2.5
29
Table C-3 STATION DATA
BTN
SUB-MENU
RANGE
DEFAULT
REMARK
11
Loop LCR Account
1: ON, 0: OFF
OFF
Station-based LOOP LCR
authorization option
12
Call Coverage
1: ON, 0: OFF
OFF
13
Call Coverage Delay Ring
0~9
0
14
Off-net Forward Disable
0:ENA, 1:DIS
Enable
Off-net Forward Activation
(Except USA version)
15
Forced ICM Mode Change
1:ON, 0:OFF
OFF
16
Active PTT Group
0~9
17
Station ICM Tenancy Group
1~15
1
18
VMIU/VMIBBoard
Sequence Number
19
SIP User ID Table Index
000-140
000
Index to Station SIP Attributes
Table
(PGM 126, Web only)
20
Camp on Tone
1: ON, 0: OFF
ON
21
Serial DSS
1: Disable
0: Enable
Enable
22
ICM Dial Tone Source
0: dial tone
1: Int/Ext 1
2: Ext 2
3: VSF
4~8:SLT MOH1~5
9~37:VSF MOH2~30
dial tone
23
ICM Ring Back Tone Source
0: ring back tone
1: Int/Ext 1
2: Ext 2
3: VSF
4~8:SLT MOH1~5
9~37:VSF MOH2~30
ring back
tone
24
UMS Attach Message
1: ON, 0: OFF
ON
PGM: 112 - Station Attributes II
1
CO Call Time Tone
1: ON, 0: OFF
OFF
2
Automatic Hold
1: ON, 0: OFF
ATD: ON
Others: OFF
3
CO Call Time Restriction
1: ON, 0: OFF
OFF
4
CO Line Access
EN/DIS
ENABLE
5
CO/IP Line Queuing
EN/DIS
ENABLE
6
CO PGM
EN/DIS
DISABLE
7
Ringing Line Preference
EN/DIS
ENABLE
8
Speed Dial Access
EN/DIS
ENABLE
9
UCD Group Service
1: ON, 0: OFF
OFF
10
Ring Group Service
1: ON, 0: OFF
OFF
11
Two Way Record
1: ON, 0: OFF
OFF

Table of Contents