iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual Issue 2.5
166
4.3.6.2 System Password – PGM 162
Passwords can protect access to the system database and maintenance functions up to twelve (12) digits.
Three passwords can be defined, Keyset Admin, Remote access, and CID.
The Maintenance password has full and unlimited access to the database and maintenance functions of the
system.
The User and Admin password have access to database items defined in Web Admin. Note there are no
default passwords.
SYSTEM PASSWORD
PRESS FLEX KEY (1-3)
Press the [PGM] button and dial 162.
KEYSET ADMIN PASSWORD
@@@@@@@@@@@@
Press the Flex button for the desired password:
- For the Keyset Admin password, press the Flex button 1.
- For the Remote access password, press the Flex button 2.
- For the CID password, press the Flex button 3.
REMOTE ACCESS PASSWORD
@@@@@@@@@@@@
Enter the desired password, up to 12 digits. To erase a password,
press the [SPEED] button.
CID PASSWORD
@@@@@@@@@@@@
Enter the desired password, up to 12 digits. To erase a password,
press the [SPEED] button.
Press the [Save] button to store the password entry.
Table 3.3.6.2-1 System Passwords
KEYSET ADMIN PASSWORD
@@@@@@@@@@@@
Admin password, configurable
database access in Keyset Admin.
REMOTE ACCESS PASSWORD
@@@@@@@@@@@@
Remote access password, full and
unlimited access to database and
maintenance functions.
CID PASSWORD
@@@@@@@@@@@@