Diagnostic information 2-133
7558-xxx
5
Check the registration motor for
proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch PRINTER MOTOR
TESTS.
4. Touch Registration motor.
Does the above component
operate properly?
Go to step 7. Go to step 6.
6
Check the registration motor for
proper connection.
Is the above component
properly connected?
Replace the registration drive
motor. Go to “Registration drive
motor removal” on page 4-147.
Replace the connections.
7
Check the 2nd transfer roller
contact retract motor for proper
operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch PRINTER MOTOR
TESTS.
4. Touch 2nd transfer rollers
retract motor (contracted).
5. Touch 2nd transfer rollers
retract motor (retracted).
Does the above component
operate properly?
Go to step 9. Go to step 8.
8
Check the 2nd transfer roller
contact retract motor for proper
connection.
Is the above component
properly connected?
Replace the printer left duplex
door assembly.
Go to “Printer left duplex door
assembly removal” on
page 4-142.
Replace the connection.
Step Action and questions Yes No