2-134 Service Manual
7558-xxx
9
Check the fuser drive motor for
proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch PRINTER MOTOR
TESTS.
4. Touch Fuser/lower redrive/
1st transfer retract motor.
Does the above component
operate properly?
Go to step 11. Go to step 10.
10
Check the fuser drive motor for
proper connection.
Is the above component
properly connected?
Replace the fuser drive motor.
Go to “Fuser/lower redrive/1st
BTR retract motor removal” on
page 4-97.
Replace the connection.
11
Check the media transport/MPF
drive motor assembly for proper
operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch PRINTER MOTOR
TESTS.
4. Touch MPF feed/lift motor
(feed).
5. Touch MPF feed/lift motor
(pick).
Does the above component
operate properly?
Go to step 13. Go to step 12.
12
Check the media transport/MPF
drive motor assembly for proper
connection.
Is the above component
properly connected?
Replace the media transport/MPF
drive motor assembly.
Go to “Media transport/MPF
drive motor removal” on
page 4-124.
Replace the connection.
Step Action and questions Yes No