EasyManua.ls Logo

Lexmark X95 series - Page 66

Lexmark X95 series
1164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-16 Service Manual
7558-xxx
Go Back
Previous
Next
121.08
Service fuser error
Heat belt (rear) temperature increase
failure
The temperature is late in reaching a
specified temperature within the specified
time.
Go to “121.08 Heat belt (rear)
temperature increase failure” on
page 2-58.
121.09
Service fuser error
Fuser temperature lag error The temperature is late in reaching a
specified temperature within the specified
time.
Go to “121.09 Fuser temperature lag
error” on page 2-58.
121.10
Service fuser error
Heat belt rotation failure Speed of belt rotation did not change
within the specified time.
Go to “121.10 Heat belt rotation failure”
on page 2-59.
121.11
Service fuser error
Fuser temperature recovery failure. The status of the fuser temperature did not
switch at the specified time.
Go to “121.11 Fuser temperature
recovery failure” on page 2-59.
121.12
Service fuser error
Incorrect fuser Wrong fuser is installed.
Go to “121.12 Incorrect fuser” on
page 2-59.
121.13
Service fuser error
Fuser thermostat failure The Fuser Assembly Thermostat is
broken.
Go to “121.13 Fuser thermostat failure”
on page 2-60.
126.01
Service fuser error
Fuser interface failure There is a a broken link between upper
engine PCBA and the fuser.
Go to “126.01 Fuser driver interface
failure” on page 2-60.
126.02
Service fuser error
Fuser driver to upper engine PCBA
interface failure
There is a broken link between upper
engine PCBA and the fuser.
Go to “126.02 Fuser driver to upper
engine PCBA interface failure” on
page 2-60.
126.03
Service fuser error
Fuser driver communication failure There is a communication error between
the fuser and upper engine PCBA
Go to “126.03 Fuser driver
communication failure” on page 2-61.
126.04
Service fuser error
Fuser driver freeze failure The processing unit of the fuser driver
PCBA has hung up.
Go to “126.04 Fuser driver freeze
failure” on page 2-61.
126.05
Service fuser error
Fuser driver high voltage error Fuser driver voltage levels has exceeded
the specified value.
Go to “126.05 Fuser driver high voltage
error” on page 2-62.
1xx service error codes
Error code Description Action

Table of Contents

Related product manuals