3 - 203
Chapter 3 Removal and Replacement Procedures (RRPs)
RRP11.10SENSOR OCT (PL11.1)
Removal
1) Remove the COVER REAR (PL 11.1). (RRP10.6)
2) Remove the COVER OCT (PL 11.1). (RRP11.4)
3) Remove the COVER FRONT (PL 11.1). (RRP11.5)
4) Release the HARNESS ASSY OCT SNR (PL 11.1) from the hooks.
5) Disconnect the connector (P/J730) of the HARNESS ASSY OCT SNR from the SENSOR
OCT.
6) Remove the SPRING ACTUATOR (PL 11.1).
7) Shift the ACTUATOR OCT (PL 11.1) in the direction of the arrows to remove it from the hooks
on both sides .
8) Release the hooks of the SENSOR OCT, and remove it from the HOUSING OCT (PL 11.1).