EasyManua.ls Logo

Rohde & Schwarz R&S SMW200A - Page 959

Rohde & Schwarz R&S SMW200A
1403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMW200A
959User Manual 1175.6632.02 ─ 30
Options: R&S SMW-B9
Manual operation: See "Peak Level" on page 171
[:SOURce<hw>]:BBIN:CHANnel<ch0>:POWer:RMS <BbinIqHsChPoRms>
Queries the estimated RMS level.
Parameters:
<BbinIqHsChPoRms> float
Range: -100 to 10
Increment: 0.01
*RST: 0
Example: See Example "Applying an external digital baseband signal (HS
DIG I/Q)" on page 955.
Options: R&S SMW-B9
Manual operation: See "Level" on page 171
[:SOURce<hw>]:BBIN:CHANnel<ch0>:SRATe <BbinIqHsChSaRat>
Sets the sample rate per channel.
Parameters:
<BbinIqHsChSaRat> float
Range: 400 to 250E6 ("System Config > Mode =
Advanced")/1250E6 ("System Config > Mode =
Standard")
Increment: 0.001
*RST: 100E6
See also Chapter 4.3.4, "Supported Digital Interfaces Depending
on the System Configuration", on page 119.
Example: See Example "Applying an external digital baseband signal (HS
DIG I/Q)" on page 955.
Options: R&S SMW-B9
Manual operation: See "Sample Rate" on page 170
[:SOURce<hw>]:BBIN:IQSWap[:STATe] <State>
If activated, swaps the I and Q channel.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Applying an external digital baseband signal (DIG
I/Q)" on page 955.
Manual operation: See "I/Q Swap" on page 161
SOURce Subsystem

Table of Contents