Remote Control Commands
R&S
®
SMW200A
959User Manual 1175.6632.02 ─ 30
Options: R&S SMW-B9
Manual operation: See "Peak Level" on page 171
[:SOURce<hw>]:BBIN:CHANnel<ch0>:POWer:RMS <BbinIqHsChPoRms>
Queries the estimated RMS level.
Parameters:
<BbinIqHsChPoRms> float
Range: -100 to 10
Increment: 0.01
*RST: 0
Example: See Example "Applying an external digital baseband signal (HS
DIG I/Q)" on page 955.
Options: R&S SMW-B9
Manual operation: See "Level" on page 171
[:SOURce<hw>]:BBIN:CHANnel<ch0>:SRATe <BbinIqHsChSaRat>
Sets the sample rate per channel.
Parameters:
<BbinIqHsChSaRat> float
Range: 400 to 250E6 ("System Config > Mode =
Advanced")/1250E6 ("System Config > Mode =
Standard")
Increment: 0.001
*RST: 100E6
See also Chapter 4.3.4, "Supported Digital Interfaces Depending
on the System Configuration", on page 119.
Example: See Example "Applying an external digital baseband signal (HS
DIG I/Q)" on page 955.
Options: R&S SMW-B9
Manual operation: See "Sample Rate" on page 170
[:SOURce<hw>]:BBIN:IQSWap[:STATe] <State>
If activated, swaps the I and Q channel.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Applying an external digital baseband signal (DIG
I/Q)" on page 955.
Manual operation: See "I/Q Swap" on page 161
SOURce Subsystem