Remote control commands
R&S
®
RTP
1335User Manual 1337.9952.02 ─ 12
REFCurve<m>:DATA[:VALues]?
Returns the data of the channel waveform points for transmission from the instrument
to the controlling computer. The data can be used in MATLAB, for example.
To set the export format, use FORMat[:DATA].
You can retrieve only Y-values, or X- and Y-values. Use EXPort:WAVeform:
INCXvalues to define this.
Suffix:
<m>
.
1..4
Reference waveform
Return values:
<Data> List of values according to the format and content settings.
Usage: Query only
22.10.2.4 Import of multichannel waveform data
Commands for saving waveform data to file are described in Chapter 22.16.5, "Wave-
form data export to file", on page 1527.Commands for reference waveforms are listed
below.
REFCurve<m>:MULTichannel:NAME.............................................................................1335
REFCurve<m>:MULTichannel:IMPort.............................................................................1335
REFCurve<m>:MULTichannel:OPEN............................................................................. 1336
REFCurve<m>:MULTichannel:NAME <MltChImptPath>
Defines the path and the file to be imported. If not path is given, the default path
C:\Users\Public\Public Documents\Rohde-Schwarz\RTx\RefWaveforms
is used.
Suffix:
<m>
.
1..4
The suffix is irrelevant.
Parameters:
<MltChImptPath> String with path and filename
Example: See REFCurve<m>:MULTichannel:IMPort on page 1335.
Usage: Asynchronous command
REFCurve<m>:MULTichannel:IMPort <MltChImptWfmSel>
Assigns a waveform from the multichannel file to a reference waveform. To import all
waveforms that are in the file, you must assign each waveform to another reference
waveform.
Waveform analysis