Remote control commands
R&S
®
RTP
2063User Manual 1337.9952.02 ─ 12
TRIGger<m>:USBThree:FRENable <Frame>, <Enabler>
TRIGger<m>:USBThree:FRAMe<n>:ENABle <Enable>
Enables or disables the checking condition for the selected frame.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
<n> *
Specifies the frame number.
Parameters:
<Enable> ON | OFF
*RST: OFF
Example:
TRIGger:USBThree:FRAMe1:ENABle ON
Enables the checking condition for the TSEQ frame.
TRIGger:USBThree:FRENable "TS1" ON
Enables the checking condition for the TS1 frame.
TRIGger<m>:USBThree:FIENable <Frame>, <Field>, <Enabler>
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:ENABle <CondEnabler>
Enables or disables the checking condition for the selected field of the selected frame.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
<n> *
Specifies the frame number.
<o> *
Specifies the field number within the frame.
Parameters:
<CondEnabler> ON | OFF
ON
Checking condition enabled
OFF
Checking condition disabled
*RST: OFF
Example:
TRIGger:USBThree:FRAMe1:FLD1:ENABle ON
Enables the checking condition for the Symbol field of the TSEQ
frame.
TRIGger:USBThree:FRENable "TS1", "Loop" ON
Enables the checking condition for the Loop field of the TS1
frame.