Remote control commands
R&S
®
RTP
2062User Manual 1337.9952.02 ─ 12
Frame number Frame name Field number Field name
32 Idle - -
33 SYNc 1 Symbol
34 SDS 1 Symbol
2 Body
TRIGger<m>:USBThree:ERENable............................................................................... 2062
TRIGger<m>:USBThree:ERRor<n>:ENABle...................................................................2062
TRIGger<m>:USBThree:FRENable............................................................................... 2063
TRIGger<m>:USBThree:FRAMe<n>:ENABle..................................................................2063
TRIGger<m>:USBThree:FIENable.................................................................................2063
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:ENABle.....................................................2063
TRIGger<m>:USBThree:DOPerator...............................................................................2064
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:DOPerator.................................................2064
TRIGger<m>:USBThree:DMIN...................................................................................... 2064
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:DMIN........................................................ 2064
TRIGger<m>:USBThree:DMAX..................................................................................... 2064
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:DMAX.......................................................2064
TRIGger<m>:USBThree:BIT......................................................................................... 2065
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:BIT........................................................... 2065
TRIGger<m>:USBThree:IOPerator................................................................................ 2065
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:IOPerator.................................................. 2065
TRIGger<m>:USBThree:IMIN........................................................................................2066
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:IMIN..........................................................2066
TRIGger<m>:USBThree:IMAX.......................................................................................2066
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:IMAX........................................................ 2066
TRIGger<m>:USBThree:ERENable <ErrorName>, <Enabler>
TRIGger<m>:USBThree:ERRor<n>:ENABle <Enable>
Defines the error type to be triggered on. You can trigger on all error types in parallel.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
<n> *
Specifies the error number.
Parameters:
<Enable> ON | OFF
*RST: ON
Example: Trigger on CRC and length errors:
TRIGger:USBThree:ERRor1:ENABle ON
Enables CRC Error.
TRIGger:USBThree:ERENable "Length Error",ON
Enables Length Error.
Protocols