Remote control commands
R&S
®
RTP
2201User Manual 1337.9952.02 ─ 12
BUS<m>:PARallel:BIT<n>[:STATe] <Assigned>
Assigns the selected digital channel to the indicated bus, displays it, and enables the
bus if the bus was disabled. That is, BUS<m>:PARallel:DISPlay:SHDI and
BUS<m>:PARallel:STATe are set to ON automatically.
If another active bus already uses the selected digital channel, the instrument disables
the other bus to avoid conflicts.
For parallel bus 1, the BUS:PAR:BIT[:STATe] command has the same effect as
DIGital<m>:DISPlay.
Suffix:
<m>
.
1..4
Selects the parallel bus.
<n> 0..15
Selects the bit of the bus word. Each bit corresponds to a digital
channel.
Parameters:
<Assigned> ON | OFF
*RST: OFF
BUS<m>:PARallel:THReshold<n> <Threshold>
Sets the logical threshold for the indicated channel group.
Alternatively, you can set the threshold with BUS<m>:PARallel:TECHnology. For
the parallel bus 1, you can also use DIGital<m>:THReshold.
See also: DIGital<m>:THCoupling
Suffix:
<m>
.
1..4
Selects the parallel bus.
<n> 1..4
Selects the channel group:
1 = dig. channels 0..3;
2 = dig. channels 4..7
3 = dig. channels 8..11
4 = dig. channels 12..15
Parameters:
<Threshold> Range: -8.0 to 8.0
Increment: 200.0e-12
*RST: 0
Default unit: V
Mixed signal option (MSO, R&S RTP-B1)