Triggers
R&S
®
RTP
258User Manual 1337.9952.02 ─ 12
In trigger sequences, another coupling of trigger levels is possible: "Couple sequence
thresholds" on page 249.
Remote command:
TRIGger<m>:SCOupling on page 1273
Serial standard
For some serial standards, the bit rate is known to the instrument. Select the standard,
and the pattern type is set automatically, no estimation is required. The serial stand-
ards are available only if the instrument is able to support its maximum nominal bit
rate, see "Maximum nominal bit rate" on page 255.
The following predefined standards are currently available:
Serial standard Nom. bit rate Pattern type
USB 2.0 480 Mbps 8b/10b
USB 3.1 Gen 1 5 Gbps 8b/10b
USB 3.1 Gen 2 10 Gbps 128b/132b
Displayport 1.1 1.296 Gbps 8b/10b
Displayport 1.2 4.32 Gbps 8b/10b
Fibre Channel 1x 1 Gbps 8b/10b
Fibre Channel 2x 2 Gbps 8b/10b
Fibre Channel 4x 4 Gbps 8b/10b
Fibre Channel 8x 8 Gbps 8b/10b
HDMI 1.2 1.32 Gbps 8b/10b
HDMI 1.4 3.4 Gbps 8b/10b
HDMI 2.0 4.8 Gbps 8b/10b
PCIe Gen 1 2.5 Gbps 8b/10b
PCIe Gen 2 5 Gbps 8b/10b
SATA Gen 1 1.5 Gbps 8b/10b
SATA Gen 2 3 Gbps 8b/10b
SATA Gen 3 6 Gbps 8b/10b
SAS Gen 1 3 Gbps 8b/10b
SAS Gen 2 6 Gbps 8b/10b
SAS Gen 3 12 Gbps 8b/10b
Thunderbolt 10G 10.3125 Gbps Single bit pattern
XAUI 3.75 Gbps 8b/10b
Remote command:
CDR:HARDware:SERStandard on page 1280