EasyManua.ls Logo

Rohde & Schwarz RTP044 - Page 665

Rohde & Schwarz RTP044
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protocol analysis
R&S
®
RTP
665User Manual 1337.9952.02 ─ 12
Make sure that:
In the [Protocol] > "Setup" tab:
The correct "Protocol" is selected.
The data sources of the serial bus are channel signals.
In the "Trigger" > "Setup" tab:
The "Trigger on" = "Single event"
The trigger "Source" = "Serial bus".
The correct "Serial bus" is selected.
Type
Selects the trigger type for 1000BASE-T1 analysis.
Remote command:
TRIGger<m>:TBTO:TYPE on page 1790
Frame Start ← Type
Triggers on the start of frame.
MAC Frame ← Type
Triggers on a media access control (MAC) frame. You can specify:
Destination address
Source address
Length/Type
Frame check
Data
Index
The frame contains addresses of the devices and MAC control information that define
how to go about transmitting and receiving frames.
Ethernet 1000BASE-T1 (option R&S
RTP-K58)

Table of Contents

Other manuals for Rohde & Schwarz RTP044

Related product manuals