Protocol analysis
R&S
®
RTP
665User Manual 1337.9952.02 ─ 12
Make sure that:
●
In the [Protocol] > "Setup" tab:
– The correct "Protocol" is selected.
– The data sources of the serial bus are channel signals.
●
In the "Trigger" > "Setup" tab:
– The "Trigger on" = "Single event"
– The trigger "Source" = "Serial bus".
– The correct "Serial bus" is selected.
Type
Selects the trigger type for 1000BASE-T1 analysis.
Remote command:
TRIGger<m>:TBTO:TYPE on page 1790
Frame Start ← Type
Triggers on the start of frame.
MAC Frame ← Type
Triggers on a media access control (MAC) frame. You can specify:
●
Destination address
●
Source address
●
Length/Type
●
Frame check
●
Data
●
Index
The frame contains addresses of the devices and MAC control information that define
how to go about transmitting and receiving frames.
Ethernet 1000BASE-T1 (option R&S
RTP-K58)