Protocol analysis
R&S
®
RTP
782User Manual 1337.9952.02 ─ 12
Remote command:
TRIGger<m>:EBTB:SYME on page 1980
Error Condition
Triggers on the selected error conditions.
Disparity error ← Error Condition
Triggers on disparity errors.
Remote command:
TRIGger<m>:EBTB:DISParityerr on page 1979
Glitching error ← Error Condition
Triggers on glitch errors.
Remote command:
TRIGger<m>:EBTB:GLITcherror on page 1980
Unknown symbol error ← Error Condition
Triggers on a symbol that is not defined by the 8b/10b.
Remote command:
TRIGger<m>:EBTB:UNK on page 1981