Configuration Guide 802.1X Commands
4.37 dot1x probe-timer alive
Use this command to set the Ruijie terminal alive interval.
dot1x probe-timer alive time
Parameter
Description
Parameter
Description
time
Terminal alive interval, in the range from 1 to 65,535 in the unit of
seconds
Defaults
The default is 250 seconds.
Command
Mode
Global configuration mode
Usage Guide
If the device does not receive the probe packet from the terminal when the terminal alive interval
expires, the device is considered offline. The default setting is recommended.
Configuration
Examples
The following example sets Ruijie terminal alive interval to 120 seconds.
Ruijie(config)# dot1x probe-timer alive 120
Related
Commands
Command
Description
N/A
N/A
Platform
Description
N/A
4.38 dot1x probe-timer interval
Use this command to set the Ruijie terminal detection interval.
dot1x probe-timer interval time
Parameter
Description
Parameter
Description
time
Terminal detection interval in the range from 1 to 65,535 in the unit of
seconds
Defaults
The default is 20 seconds.
Command
Mode
Global configuration mode
Usage Guide
The default setting is recommended.
Configuration
The following example sets Ruijie terminal detection interval to 30 seconds.