Use this command to configure the periodic notification function of the CPE.
If the time for starting periodical notification is not specified, periodical notification starts after the
periodical notification function is enabled. The notification is performed once within every
notification interval.
If the time for starting periodical notification is specified, periodical notification starts at the
specified start time. For instance, if the periodical notification interval is set to 60 seconds and
the start time is 12:00 am next day, periodical notification will start at 12:00 am next day and
once every 60 seconds.
The narrower periodical notification interval allows the ACS to track the latest CPE status more
accurately. However, narrower periodical notification interval brings about more sessions
between the CPE and the ACS, consuming more resources of them. So the user should specify
the periodical notification interval of the CPE to a reasonable value according to the network
performance and the ACS performance.
The following example specifies the periodical notification interval of the CPE to 60 seconds.
Ruijie#config terminal
Enter configuration commands, one per line. End with CNTL/Z.
Ruijie(config)#cwmp
Ruijie(config-cwmp)#cpe inform interval 60
Ruijie(config-cwmp)#
Use this command to configure the CPE password to be authenticated for the ACS to connect to the
CPE. Use the no form of this command to cancel the configuration.