Command Reference Interface Commands
Number of line pairs included. For example, the twisted pair includes
four pairs of lines.
Status of the current line pair: OK, Short or Open. In general, the 100M
twisted pairs A and B are OK, C and D are Short. The 1000M twisted
pairs A, B, C and D are all OK.
Length of the line in meter. Only the length of the line pair whose status
is OK takes effect. Since the length is calculated based on the
transmission time of signal, there may have a certain difference. The
length of the line pair whose status is Short or Open is the length from
the port to the faulty point.
Use this command to set the interval for calculating load on the interface. Use the no form of this
command to restore the default setting.
In the range from 5 to 600 in the unit of seconds.
Interface configuration mode
This command is used to set the interval for calculating load on the interface. In general, the numbers
of incoming and outgoing packets and bytes are calculated every 10 seconds. For example, if the
parameter is set to 180 seconds, the following outcome is displayed when the show interface
gigabitEthernet 0/1 command is run.
3 minutes input rate 15 bits/sec, 0 packets/sec
3 minutes output rate 14 bits/sec, 0 packets/sec