Appendix 3: VDRPARAMS.INI File, Rev. 1.2
VDR-100G3/G3S Installation Manual 18/01/2009
9
A3.9 Sample VDRPARAMS.INI File
[GENERAL PARAMS]
//Released with VDR-100G3 Record Application version 6.01.00
autoStart = 1 // 0=disable, 1=enable
Last Modified=02/27/2008 16:41:00
[COMMON PARAMS]
totalDuration =720 // time duration of a dataset
directoryCountGAP=10 // declare extra directories to simplify logic (1 to 20)
dirInterval = 60 // time duration of a directory, in minutes (30 - 1440)
upperLimit = 2 // threshold to stop deleting extra data, in disk space percentage
lowerLimit = 1 // threshold to start deleting extra data, in disk space percentage
listenToModem = 0 // 0 = disabled, 1 = enabled; default is 0
startLyngso = 0 // 0 = disabled, 1 = enabled; default is 0
LyngsoPath = \\ows1\c\vdr
[UPS]
powerFailRecordTime = 120 // time, in minutes, to continue recording after a power failure; 1-180 minutes
COMPort = COM2
[STORAGE]
primaryLoc=D:\VDR_DATA
mirrorLoc=E:\VDR_DATA_MIRROR
archiveLoc=F:\VDR_DATA_ARCHIVE
tmpDrive = "D:\"
fullDownloadEnabled = 1 // 0 = disabled, 1 = enabled; default is 1
VideoToFRM = 1 // 0 to 4; default is 1, 0 = all video to FRM
hardenedStorage = 1 // 0=disable, 1=enable, 2 = Dual FRM, default is 0
hardenedFormat = 5 // 1=L3 HVR/SVR, 2= Unused, 3=Jotron, 4=Rutter-ACR Float-Free, 5=Rutter
Fixed
secondaryHardenedFormat = 4 // 1=L3 HVR/SVR, 2= Unused, 3=Jotron, 4=Rutter-ACR Float-Free, 5=Rutter
Fixed
// If using an L3 HVR/SVR Fixed Capsule as the primary FRM, use IP "192.168.0.2"
L3HVR-serverPort = 5000
L3HVR-IP = "192.168.0.2"
L3HVR-numStreams = 3 // default is 3
L3HVR-streamName1 = "AUDIO"
L3HVR-streamName2 = "NMEA"
L3HVR-streamName3 = "VIDEO"
L3HVR-errorChecking = 1 // 0 = disable, 1 = enable; default is 1
L3HVR-compressNMEA = 1 // 0 = disable, 1 = enable; default is 1
// stream type may be AUDIO, VIDEO or NMEA; default is AUDIO
L3HVR-streamType1 = "AUDIO"
L3HVR-streamType2 = "NMEA"
L3HVR-streamType3 = "VIDEO"
// If using a Jotron Float-Free Capsule as the primary FRM, use IP "192.168.0.37":
// If using a Jotron Float-Free Capsule as the secondary FRM, use IP "200.200.200.37".
NetworkHVR-IP = "192.168.0.37"
NetworkHVR-compressNMEA = 0 // 0 = disable, 1=enable; default is 0
NetworkHVR-DriveLetter = "X"
// If using a Rutter-ACR Float-Free Capsule as the primary FRM, use IP "192.168.0.100".
// If using a Rutter-ACR Float-Free capsule as the secondary FRM, use IP "200.200.200.100".
CACRFFMC-IP = "192.168.0.100"
CACRFFMC-compressNMEA = 0 // 0 = disable, 1=enable; default is 0
// If using a Rutter Fixed Capsule as the primary FRM, use IP "192.168.0.50".
RutterFixed-IP="192.168.0.50"
RutterFixed-DriveLetter="Z"
RutterFixed-compressNMEA = 0 // 0 = disable, 1=enable; default is 0